Permit #2026051164
Permit Details
Status: APPLY
| Parcel Id: 07-11-31-7025-000G0-0190 |
| Block: 000G0 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: 856-776-3930 |
| Location Address: 1000 PALM COAST PKWY SW |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| NOC: Unknown |
| Applicant name: NEFTALI DEJESUS III |
| Owner: PATEL PALM COAST PLAZA LLC |
|
Address 644 CESERY BLVD #106 JACKSONVILLE, FL 32211 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤2,000.00 |
| Job Description: UNIT 206 - 210 ADDING WALLS TO MAKE ROOMS |
| Type: CN |
Contractor
1621 BUILDING AND REMODELING LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
389 PALM COAST PARKWAY SW UNIT 3-N PALM COAST, FL 32137 |
CGC1534626 (Exp: 08/31/2026) | 386-597-5984 |
Inspection History
| Type | Request Date | Result | Inspector |
| ABOVE CEILING | |||
| BUILDING FINAL | |||
| FIRE FINAL | |||
| U - UTILITY COMMERCIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | HOLD | 05/28/2026 | 06/11/2026 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING COD-EXISTING BUILDING (FBCEB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.) FLORIDA ADMINISTRTIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.) 1. Permit application indicates this is a single unite 20 thorugh 210. Plans are only for Unit 206. If 206, 207, 208, 209 and 210 is a single tenant space, then provide a complete floor plan for the entire tenant space. If work is limited to a single tenant space / unit, then revise permit application accodingly. AHJ. 2. Provide occupancy classification. FBCB 302., 107.3.5 3. Provide building Construction Type FBCB 602.1 4. Provide classification of work / alteration level. FBCEB 601, 602, 603, 604. 5. Identify / label all rooms FBCB 107.2. 6. Provide wall sections from surface to surface, include all framing materials, finish materials, fastening to deck and to roof-ceiling assembly above. FBCB 107.2,107.3.5, CHAPTER 22, CHAPTER 23 7. Provide door schedule showing width and height of doors, accessible door hardware. Include door clearance dimension with door open to 90 degrees. FBCA 206, 309, 404, 8. Provide floor finishes. FBCA 302. 9. Provide reflected ceiling plan showing ceiling type, locatio of lighting, mechanical supply and return diffusers and sprinkler heads. Note any items to be relocated as a result of creating the new rooms. FBCB 107.2, 107.3.5 A COUPLE OF NOTES: WE HAVE A NEW BUSINESS TAX RECEIPT SUBMITTED FOR A MUSICAL TRAINING SCHOOL, IN UNIT 209 AND THEY INDICATED THEY WOULD BE MAKING CHANGES CREATING SOME MUSIC STUDY / PRACTICE ROOMS. COULD THIS BE THE SAME TENANT YOU ARE DOING WORK FOR? IF SO, LET US KNOW AND CHANGE THE UNIT NUMBER TO 209. IF THE ALTERATIONS TO THIS TENANT SPACE ARE SUCH THAT THE NEW WALLS WON'T EXEND TO OR ABOVE THE CEILING AND NOTHING IN THE CEILING SUCH AS LIGHTING, SPRINLER HEADS, MECHANCIAL SUPPLY AND RETURN DIFFUSERS WON'T NEED TO BE REMOVED, THEN ADD NOTES TO PLANS OR PROVIDE A SCOPE OF WORK THAT GIVES US A BETTER UNDERSTANDING, OTHERWISE, WE ARE ASSUMING THAT ADDITIONAL ALTERASTIONS AS NOTED IN OUR REVIEW COMMENTS ARE NECESSARY AND THEREFORE DESIGN MUST BE PROVIDED. PLEASE CALL OR EMAIL WITH ANY QUESTIONS: PATRICK BUCKLEY 386-986-3786 PBUCKLEY@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 05/28/2026 | 05/29/2026 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/28/2026 | 06/02/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Label rooms. 2. Show lighting, switches and outlets. 3. More comments may come with more information. | |||
| FI1 | HOLD | 05/28/2026 | 06/02/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Show exit signs so they are visible when walking out of the rooms. FFPC 8th edition ch 39 2. Show location of fire extinguishers. | |||
| MECH | HOLD | 05/28/2026 | 06/11/2026 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-MECHANICAL (FBCM), FLORIDA BUILDING CODE-EXISTING BUILDING (FBCEB), FLORIDA BUILDING CODE-ENERGY CONSERVATON (FBCEC), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AUTHORITY HAVING JURISDICTION (AHJ). See plan review notes and comments under the Building Review. 1. If new walls extend to or above the ceiling, then reconfiguaration of the HVAC system supply and return air duct systems is necessary. Reconfiguratoin will require a mechanical contraactor and submittal of ventilation air calcualtions, energy calculations and plans for duct changes and any equipment changes that may be necessary. FBCEB 601.1, 602.1, 603.1,604.1, 809.1, 811.1, FBCM 401.2, 401.3, 403.1, TABLE 403.3.1.1. PLEASE BE ADVISED, DEPENDING ON RESPONSES, ADDITIONAL PLAN REVIEW COMMENTS MAY BE FORTCOMING. | |||
| PLUM | CANCEL | 05/28/2026 | 06/11/2026 |
| Note: No plumbing alteratons are proposed. | |||
| UD1 | COMPLETE | 05/28/2026 | 06/01/2026 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| UD2 | COMPLETE | 05/28/2026 | 05/29/2026 |
| Note: Released By: DAN LEMONCELLO - - | |||
| ELEC | PENDING | ||
| FI1 | PENDING | ||
| BLD | PENDING | ||
| MECH | PENDING |