I want to search for...

Permit #2026060018

Permit Details

Status: APPLY

Parcel Id: 07-11-31-7030-00210-0170
OPENED PORCH (WITH ROOF) : 120 sqft
CONDITIONED SPACE: 2960 sqft
GARAGE: 1000 sqft
Total Square Footage: 4080 sqft
Block: 00210
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 863-647-5815
Location Address: 31 RAINSTONE LN
Type: DU - DUPLEX
NOC: NO DOCUMENTATION
Applicant name: MARK ALLAN HULBERT
Owner: HULBERT HOMES INC

Address

5116 S LAKELAND DRIVE

LAKELAND, FL 33813

Lot: 0170
Contracted Stated Job Value: ¤245,000.00
Job Description: DUPLEX
Type: CN

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

DANIEL JOSEPH SCHWARZKOPF
Status Location Address State License Number Phone
ACTIVE

4601 E MOODY BLVD D6

PALM COAST, FL 32164

EC13010351 (Exp: 08/31/2026) 386-313-6211
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
IAN ALAN BRENNER
Status Location Address Mailing Address State License Number Phone
ACTIVE

691 GARDEN COMMERCE PKWY

WINTER GARDEN, FL 34787

STE 170

WINTER GARDEN, FL 34787

CCC1331270 (Exp: 08/31/2026) 407-649-1333
LARRY DEWITT DEAN
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 48070

JACKSONVILLE, FL 32207

CFC056659 (Exp: 08/31/2026) (904)994-6440

Inspection History

Type Request Date Result Inspector
FORMBOARD SURVEY (OFFICE USE ONLY)
GEOTECHNICAL REPORT APPROVAL (OFFICE USE)
PLUMBING 1ST ROUGH UNDERGROUND
GRAVITY SEWER TEST
SEWER TIE IN
ELECTRIC - EARLY POWER
MONOLITHIC SLAB
LATH/BRICK/ WATER BARRIER
TIE BEAM / LINTEL
ALL ROUGH
FIREWALL FRAMING
FIREWALL DRYWALL NAILING
FIREWALL FINAL
WALL SHEATHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL
ROOF VALLEY & METAL
INSULATION
DRYWALL NAILING
BLD - BUILDING FINAL
WATER METER INSTALLATION REQUEST
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SWALE COMPLETE 06/03/2026 06/09/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD HOLD 06/01/2026 06/04/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Plan sheet pg. 2 - firewall detail- 1/2" type X drywall not allowed. Minimum is 5/8 type X. Please revise. 2. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp (shop drawing review) indicating acceptance and approval of truss design (Not wet seal) 3. Roofing worksheet FL# 5444-R21 not underlayment. 4. Product Approval form FL# 17676-R21 not valid.
CUSVC COMPLETE 06/01/2026 06/05/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 06/01/2026 06/02/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit Electrical load calculations 2. Submit a duplex riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85
ENGIN1 COMPLETE 06/01/2026 06/03/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 06/01/2026 06/05/2026
LOCATE COMPLETE 06/01/2026 06/03/2026
Note: Released By: IVAN SANDERSON - -
MECH HOLD 06/01/2026 06/05/2026
Note: Held By: KENNETH SANDOE - - KSANDOE@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2023 8Th edition 2. When submitting include signed state card
SW1 HOLD 06/01/2026 06/08/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - There is a low point of 27.45' in the back yard on the right. There shall be positive fall every 20'. - Front property line shall be even with or higher than the edge of pavement. - Please provide a benchmark reference in the NAVD88. Please feel free to call or email if there are any questions or concerns.
ZON COMPLETE 06/01/2026 06/03/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ELEC PENDING
BLD PENDING
MECH PENDING
SW1 PENDING

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER- TURN ON ¤100.00
PEP TANK INSTALL ¤1,513.48
WASTEWATER MAIN EXTENSION IMPA ¤4,770.00
WATER METER W/ TAP ¤4,653.86
SEWER CREDIT (¤2,016.00)
SEWER CAPITAL FACILITY ¤8,830.00
WATER CAPITAL FACILITY FEE ¤8,168.50
WATER MAIN EXTENSION IMPACT ¤1,960.26
Fees Total Due: ¤27,980.10 Total Paid: ¤0.00