Permit #2026060028
Permit Details
Status: APPLY
| Parcel Id: 07-11-31-7058-00840-0030 |
| OPENED PORCH (WITH ROOF) : 98 sqft |
| CONDITIONED SPACE: 2980 sqft |
| GARAGE: 1000 sqft |
| Total Square Footage: 4078 sqft |
| Block: 00840 |
| Subdivision: 2215 - SECTION 58-SEMINOLE PARK |
| Job Phone: 863-647-5815 |
| Location Address: 102 SECRETARY TRL |
| Type: DU - DUPLEX |
| NOC: NO DOCUMENTATION |
| Applicant name: MARK ALLAN HULBERT |
| Owner: HULBERT HOMES INC |
|
Address PO BOX 6254 LAKELAND, FL 33813 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤242,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
DANIEL JOSEPH SCHWARZKOPF
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD D6 PALM COAST, FL 32164 |
EC13010351 (Exp: 08/31/2026) | 386-313-6211 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
Inspection History
| Type | Request Date | Result | Inspector |
| FORMBOARD SURVEY (OFFICE USE ONLY) | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| MONOLITHIC SLAB | |||
| LATH/BRICK/ WATER BARRIER | |||
| TIE BEAM / LINTEL | |||
| ALL ROUGH | |||
| FIREWALL FRAMING | |||
| FIREWALL DRYWALL NAILING | |||
| FIREWALL FINAL | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL | |||
| WATER METER INSTALLATION REQUEST | |||
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SWALE | COMPLETE | 06/03/2026 | 06/09/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/01/2026 | 06/03/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Plan sheet pg. 2 - firewall detail- 1/2" type X drywall not allowed. Minimum is 5/8 type X. Please revise. 2. Trusses A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp (shop drawing review) indicating acceptance and approval of truss design (Not wet seal) 3. Roofing worksheet FL# 5444-R21 not underlayment. 4. Product Approval form FL# 17676-R21 not valid. 5. Goetech Deferal for wrong address. Provide geotechnical investigation report in accordance with FBCB Section 1803.2. Report to be conducted per Sections 1803.3 through 1803.5. Completed report shall comply with Section 1803.6. Report shall be signed and sealed by a Florida licensed professional engineer in accordance with F.S. 471.025 and Florida Administrative Code Sections 61G15-30.001 and 61G15-23.001 through .005. You can request a deferred submittal by providing a letter on company letterhead. | |||
| CUSVC | PENDING | 06/01/2026 | |
| ELEC | HOLD | 06/01/2026 | 06/02/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit Electrical load calculations 2. Submit a duplex riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85 | |||
| ENGIN1 | COMPLETE | 06/01/2026 | 06/03/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/01/2026 | 06/05/2026 |
| LOCATE | COMPLETE | 06/01/2026 | 06/03/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 06/01/2026 | 06/05/2026 |
| Note: Released By: KENNETH SANDOE - - KSANDOE@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/01/2026 | 06/08/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Benchmark shall be in PP, hydrant, or manhole cover. Nail in pavament is only used as a last resort if none of the previous options are available. - Please provide the FFE of the nearest improved lot on the right side of this home - The FFE if this lot has no tolerance to be any higher. The maximum between adjacent FFEs are ±10"(0.833') | |||
| ZON | COMPLETE | 06/01/2026 | 06/03/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| ELEC | PENDING | ||
| BLD | PENDING | ||
| SW1 | PENDING |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WASTEWATER PERM INSPECTION | ¤55.00 | |
| Fees | Total Due: ¤55.00 | Total Paid: ¤0.00 |