Permit #2015010295

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7033-00450-0080
CONDITIONED SPACE: 940 sqft
Total Square Footage: 940 sqft
Block: 00450
Subdivision: 2184 - SECTION 33-ROYAL PALMS
Job Phone: 386-437-2997
Location Address: 117 RED MILL DR
Type: BA - BUILDING ADDITION
Issue Date: 02/04/2015
NOC: RECORDED
Applicant name: THOMAS CHARLES TALLAKSEN JR.
Owner: RHODES, DEBRA

Address

1 LAKE PLACID PLACE

PALM COAST, FL 32137

Lot: 0080
Contracted Stated Job Value: ¤80,000.00
Job Description: REAR ADDITION
Type: CN

Contractor

TALLY'S CONSTRUCTION CO
Status Location Address State License Number Phone
INACTIVE

503 SOUTH OLD DIXIE HWY

BUNNELL, FL 32110

CRC1330234 (Exp: 08/31/2024) 386-931-2990

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32136

CAC048127 (Exp: 08/31/2018) 386-445-5023 386-446-4614
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
THOMAS CHARLES TALLAKSEN JR.
Status Location Address State License Number Phone Fax
INACTIVE

503 SOUTH OLD DIXIE HWY

BUNNELL, FL 32110

CCC1327743 (Exp: 08/31/2024) 386-931-2990 (386)437-2279

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 08/21/2015 FINAL APPROVED MBACON
BLD - BUILDING FINAL 08/19/2015 APPROVED JHINDMAN
FINAL SURVEY (OFFICE USE ONLY) 08/13/2015 APPROVED DREWIS
ALL ROUGH 05/22/2015 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 05/22/2015 APPROVED DROCKWELL
ALL ROUGH 05/07/2015 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 5/7/2015 10:22:21 AM REVISE PLAN TO SHOW WATER HEATER LOCATION AND PROVIDE ELECT NOTATION/PROVIDE ACCESS TO ATTIC WITH LIGHT/ANCHOR ALL WINDOWS TO BLOCK/ADD POCKET DOOR TO REVISED PLAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/09/2015 APPROVED DROCKWELL
TIE BEAM / LINTEL 03/24/2015 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 03/23/2015 APPROVED JHINDMAN
MONOLITHIC SLAB 03/09/2015 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 03/05/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 3/5/2015 11:36:15 AM MINIMUM DEPTH ON FOOTERS UNDISTURBED SOIL..FBC..403.1.4 (SHOWN ON DETAIL). DETAIL SHOWS 24" #4 BARS ACCROSS @ 36" OC FOR FM APPLICATIONS.
PLUMBING 1ST ROUGH UNDERGROUND 02/23/2015 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
ELEC COMPLETE 08/20/2015 08/20/2015
Note: Released By: JHINDMAN
SW1 COMPLETE 08/12/2015 08/13/2015
Note: Released By: DREWIS FINAL SURVEY
ELEC HOLD 06/02/2015 06/09/2015
Note: 1. The fire alarm must be submitted as a separate permit.. The permit submission must include battery calculations and manufacturers specifications on the panel and devices.
ELEC COMPLETE 05/21/2015 05/21/2015
BLD COMPLETE 05/20/2015 05/21/2015
ELEC HOLD 05/20/2015 05/21/2015
Note: 1. Provide a separate permit for the fire alarm
PLUM COMPLETE 05/20/2015 05/21/2015
Note: Revision - added water heater.
SW1 COMPLETE 03/20/2015 03/23/2015
Note: Released By: JHINDMAN foundation s
PLUM COMPLETE 02/03/2015 02/03/2015
MECH COMPLETE 01/29/2015 02/02/2015
PLUM HOLD 01/29/2015 02/02/2015
Note: Previous comment dated 1-26-15 shall be addressed - Submitted correction of riser diagram using individual venting shall comply also with 2010 FBCR P3104.4 which states- Every dry vent shall rise vertically to the minimum of 6 inches above the flood level rim of the highest trap or trap fixture being vented. Unfortunately, the vent of lavatories (common vented) is located below the flood level rim of the highest trap being vented.
ELEC COMPLETE 01/21/2015 01/23/2015
PLUM HOLD 01/21/2015 01/26/2015
Note: Submitted correction of riser diagram using individual venting shall comply also with 2010 FBCR P3104.4 which states- Every dry vent shall rise vertically to the minimum of 6 inches above the flood level rim of the highest trap or trap fixture being vented. Unfortunately, the vent of lavatories (common vented) is located below the flood level rim of the highest trap being vented.
MECH HOLD 01/21/2015 01/26/2015
Note: Energy Performance Level (EPL) Display Card shall be signed by builder per 2020 FBCEC 405.4.3.
BLD COMPLETE 01/15/2015 01/16/2015
ELEC HOLD 01/15/2015 01/15/2015
Note: 1. Provide a disconnect for the Air Handler unit 2008 NEC art 422.
MECH HOLD 01/15/2015 01/16/2015
Note: Provide energy calculation, equipment sizing calculation and duct system layout per 2010 FBC 107.2.1/FBCEC 403.6.
PLUM HOLD 01/15/2015 01/16/2015
Note: Revise the venting system of the new bathroom to comply either per 2010 FBCR P3106 (individual vent) or P3108 (wet venting).
SW1 COMPLETE 01/15/2015 01/15/2015
ZON COMPLETE 01/15/2015 01/16/2015

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 08/13/2015
REVISION ¤40.00 08/13/2015
REINSPECTION FEE ¤40.00 08/13/2015
REINSPECTION FEE ¤40.00 03/23/2015
REMODEL/ADDITION/ACCES INSPECT ¤41.60 02/04/2015
SITE PLAN 20 ¤20.00 02/04/2015
SURCHARGE FS 533.721 ¤7.06 02/04/2015
SURCHARGE - FS 468.631 ¤7.06 02/04/2015
STORM WATER PERMIT FEES ¤80.00 02/04/2015
ADMIN FEE ¤20.00 02/04/2015
ELECTRIC FEE ¤122.40 02/04/2015
MECHANICAL FEE ¤122.40 02/04/2015
PLAN CHECK FEE ¤41.60 02/04/2015
PLUMBING FEE ¤122.40 02/04/2015
Fees Total Due: ¤0.00 Total Paid: ¤744.52