I want to search for...
Permit #2024050012
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7025-00540-0440 |
| Total Square Footage: 2273 sqft |
| Block: 00540 |
| Subdivision: 7025 - |
| Job Phone: 321-439-6423 |
| Location Address: 25 PAUL LN |
| Type: ME - MECHANICAL |
| Issue Date: 05/02/2024 |
| NOC: Unknown |
| Applicant name: JACOB A ANZANI |
| Owner: LOWE DARNELL E |
|
Address 25 PAUL LANE PALM COAST, FL 32164 |
| Lot: 0440 |
| Contracted Stated Job Value: ¤5,000.00 |
| Job Description: HVAC CO Like for Like |
| Type: CN |
Contractor
BLUE LINE ROOFING
| Status | Location Address | State License Number | Phone |
| INACTIVE |
881 BARTON BOULEVARD ROCKLEDGE, FL 32955 |
CAC1821980 (Exp: 08/31/2026) | 321-439-6423 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 05/31/2024 | FINAL APPROVED | JSTEWART |
| Note: 5/22/2024 - PREVIOUS INSPECTION NOTES 5/22/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. Please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed if requesting a Virtual Re-inspection.(Pictures are not approved). 1). New disconnect is behind the unit so that the door will not open at least 90degrees minimum and has an open knock out that needs a blank plug. 2). Previously noted item 4 remains unresolved. New AHRI document on site is still missing region information as required. New inspection due to canceled inspection 5/17/2024 - PREVIOUS INSPECTION NOTES 5/17/24: 1). Disconnect at AHU has cover removed. Needs new cover or disconnect. NEC 330.40 2). MC cable sleeve is separating and not connected securely into the fitting at the AHU. NEC 314.29 (A) 3). Please seal hole in AHU closet ceiling where MC cable enters attic. (FBC-R302.11) 4). AHRI document is missing region information as required. | |||
| HVAC FINAL | 05/22/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/22/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. Please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed if requesting a Virtual Re-inspection.(Pictures are not approved). 1). New disconnect is behind the unit so that the door will not open at least 90degrees minimum and has an open knock out that needs a blank plug. 2). Previously noted item 4 remains unresolved. New AHRI document on site is still missing region information as required. New inspection due to canceled inspection 5/17/2024 - PREVIOUS INSPECTION NOTES 5/17/24: 1). Disconnect at AHU has cover removed. Needs new cover or disconnect. NEC 330.40 2). MC cable sleeve is separating and not connected securely into the fitting at the AHU. NEC 314.29 (A) 3). Please seal hole in AHU closet ceiling where MC cable enters attic. (FBC-R302.11) 4). AHRI document is missing region information as required. | |||
| HVAC FINAL | 05/21/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 5/17/2024 - PREVIOUS INSPECTION NOTES 5/17/24: 1). Disconnect at AHU has cover removed. Needs new cover or disconnect. NEC 330.40 2). MC cable sleeve is separating and not connected securely into the fitting at the AHU. NEC 314.29 (A) 3). Please seal hole in AHU closet ceiling where MC cable enters attic. (FBC-R302.11) 4). AHRI document is mission region information as required. | |||
| HVAC FINAL | 05/17/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/17/24: 1). Disconnect at AHU has cover removed. Needs new cover or disconnect. NEC 330.40 2). MC cable sleeve is separating and not connected securely into the fitting at the AHU. NEC 314.29 (A) 3). Please seal hole in AHU closet ceiling where MC cable enters attic. (FBC-R302.11) 4). AHRI document is mission region information as required. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/29/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/17/2024 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/02/2024 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/02/2024 |
| ADJUSTMENT 10% | (¤9.00) | 05/02/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/02/2024 |
| INSPECTION - MECHANICAL | ¤60.00 | 05/02/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤165.00 |