Permit #2024050971

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7004-00030-0050
Block: 00030
Subdivision: 7004 -
Job Phone: 386-931-3742
Location Address: 3 CHRISTOPHER CT N
Type: PL - PLUMBING
Issue Date: 06/12/2024
NOC: Unknown
Applicant name: HEATH EDWARD SANFORD
Owner: HESTER DAN M & DONNA A H&W

Address

3 NORTH CHRISTOPHER CT

PALM COAST, FL 32137

Lot: 0050
Contracted Stated Job Value: ¤2,100.00
Job Description: master bath remodel -move w/c, shower, tub lav
Type: CN

Contractor

SANFORD PLUMBING INC
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 08/14/2024 FINAL APPROVED MGIBSON
PLUMBING 2ND ROUGH 06/26/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 SAW TERMITE BOND OK TO PLACE CONCRETE
PLUMBING 1ST ROUGH UNDERGROUND 06/17/2024 APPROVED - AS NOTED MGIBSON
Note: SAW TERMITE BOND OK TO PLACE CONCRETE
PLUMBING 2ND ROUGH 06/14/2024 CANCELLED BY APPLICANT WEB

Review History

Department Status Date In Date Out
PLUM COMPLETE 06/11/2024 06/12/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM Repeat Comments. 3. Provide type of shower prefabricated shower base, floor or receptor. 4. Provide type of shower enclosure or wall finishes. If tile, provide tile backer board manufacturer and type. 5. Relocation of bath lavatories may require changes to electrical receptacle if the change in location means either lavatory sink is more than 36 inches away from the receptacle. If one or more electrical receptacles must be relocated to serve the lavatory sinks, then an electrician is a required subcontractor and the circuit for the receptacle must be changed to 20 amp, and be GFCI protected. Show location of electrical receptacle(s) in relation to both lavatory sinks and indicate whether existing or new. If new, provide electrical sub-contractor.
PLUM HOLD 05/29/2024 05/29/2024
Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM Repeat Comments. 3. Provide type of shower prefabricated shower base, floor or receptor. 4. Provide type of shower enclosure or wall finishes. If tile, provide tile backer board manufacturer and type. 5. Relocation of bath lavatories may require changes to electrical receptacle if the change in location means either lavatory sink is more than 36 inches away from the receptacle. If one or more electrical receptacles must be relocated to serve the lavatory sinks, then an electrician is a required subcontractor and the circuit for the receptacle must be changed to 20 amp, and be GFCI protected. Show location of electrical receptacle(s) in relation to both lavatory sinks and indicate whether existing or new. If new, provide electrical sub-contractor.
PLUM HOLD 05/21/2024 05/22/2024
Note: Held By: JIM WALKER - (386)529-4112 - JWALKER@PALMCOASTGOV.COM REPEAT COMMENTS 1. Provide existing floor plan so the proposed changes can be compared to current conditions. 2. If new wall(s) are to be provided, provide framing detail or add to scope of work. 3. Provide type of shower prefabricated shower base, floor or receptor. 4. Provide type of shower enclosure or wall finishes. If tile, provide tile backer board manufacturer and type. 5. Relocation of bath lavatories may require changes to electrical receptacle if the change in location means either lavatory sink is more than 36 inches away from the receptacle. If one or more electrical receptacles must be relocated to serve the lavatory sinks, then an electrician is a required subcontractor and the circuit for the receptacle must be changed to 20 amp, and be GFCI protected. Show location of electrical receptacle(s) in relation to both lavatory sinks and indicate whether existing or new. If new, provide electrical sub-contractor. Added Note. Please ensure the new set of plans submitted clearly show. Existing floor plan and New floor plan.
PLUM HOLD 05/20/2024 05/21/2024
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM 1. Provide existing floor plan so the proposed changes can be compared to current conditions. 2. If new wall(s) are to be provided, provide framing detail or add to scope of work. 3. Provide type of shower prefabricated shower base, floor or receptor. 4. Provide type of shower enclosure or wall finishes. If tile, provide tile backer board manufacturer and type. 5. Relocation of bath lavatories may require changes to electrical receptacle if the change in location means either lavatory sink is more than 36 inches away from the receptacle. If one or more electrical receptacles must be relocated to serve the lavatory sinks, then an electrician is a required subcontractor and the circuit for the receptacle must be changed to 20 amp, and be GFCI protected. Show location of electrical receptacle(s) in relation to both lavatory sinks and indicate whether existing or new. If new, provide electrical sub-contractor.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 10% (¤12.25) 06/12/2024
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/12/2024
INSPECTION - PLUMBING ¤60.00 06/12/2024
PLAN REVIEW - MISC 32.50 ¤32.50 06/12/2024
SURCHARGE FS 533.721 ¤2.00 06/12/2024
SURCHARGE - FS 468.631 ¤2.00 06/12/2024
Fees Total Due: ¤0.00 Total Paid: ¤114.25