I want to search for...
Permit #2026030338
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7024-00330-0070 |
| Block: 00330 |
| Subdivision: - |
| Job Phone: 386-795-9854 |
| Location Address: 24 PRETORIA LN |
| Type: ME - MECHANICAL |
| Issue Date: 03/20/2026 |
| NOC: Unknown |
| Applicant name: DAVID JOSHUA COX |
| Owner: SOTO ANSELMO ALONSO & KAREN BARRETO PUCA H&W |
|
Address 24 PRETORIA LANE PALM COAST, FL 32164 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤11,619.07 |
| Job Description: HVAC CO LIKE FOR LIKE |
| Type: CN |
Contractor
ONE HOUR AIR CONDITIONING & HEATING
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 S. RIDGEWOOD AVE # B SOUTH DAYTONA, FL 32119 |
CAC1817215 (Exp: 08/31/2026) | 386-262-1247 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 05/07/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/7/2026 11:39:23 AM *** 5/7/26: 1). Breaker for AHU does not match the required amperage for the unit. (Min. - 30.8amps / Max. - 35amps --- 30amp installed). NEC 440.4 2). Missing the Notice to Homeowner sticker on electrical box stating that the AHU is located in the attic as required. FBC-M1401.1 > FBEC-R403.3.6 -- Please see code for full requirements. NOTE: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. | |||
| HVAC FINAL | |||
| Note: 5/7/2026 - PREVIOUS INSPECTION NOTES 5/7/26: 1). Breaker for AHU does not match the required amperage for the unit. (Min. - 30.8amps / Max. - 35amps --- 30amp installed). NEC 440.4 2). Missing the Notice to Homeowner sticker on electrical box stating that the AHU is located in the attic as required. FBC-M1401.1 > FBEC-R403.3.6 -- Please see code for full requirements. NOTE: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/20/2026 |
| INSPECTION - MECHANICAL | ¤60.00 | 03/20/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/20/2026 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/20/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤94.00 |